MazicBay Diagnostics
MAZICBAYDiagnostics
FTC Reader Disclosure: When you purchase or register through links on our site, we may earn an affiliate commission at no extra cost to you. Read our Editorial & Advertising Policy.

P0117 on Acura Integra

Engine Coolant Temperature Sensor 1 Circuit Low

Factory diagnostic protocol and troubleshooting wire for fault code P0117 specifically for the Acura Integra (2023–2026, 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP)).

Verified OEM Telemetry & Field Repair Tree
Acura Integra2023–2026
Acura Integra
Sedan1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP)
Reliability
Sensor Voltage Ref
0.1V – 5.0V Ref
Integra SAE Mode $01
ECU Network Bus
500 kbps CAN-FD
ISO 15765-4 Compliant
Drivability Status
Not Recommended
High urgency level
Est. Repair Cost
$80 - $250 (DIY: $20 - $60)
Parts & Labor DIY
Check P0117 On Another Acura Model:
Diagnose P0117 on Specific Integra Model Year:

1. Symptoms of P0117 on Acura Integra

When the Engine Control Module (ECM/PCM) on your Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP)) logs fault code P0117, drivers commonly observe:

Check Engine Light on on Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP))
Radiator radiator fans running constantly at high speed on Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP))
Temperature gauge pegged at maximum H or not reading on Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP))
Engine hard starting when cold (flooding from excess fuel) on Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP))
Poor gas mileage and rough idling on Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP))
Acura Integra OBD-II Port Location
The 16-pin diagnostic connector is located Under driver dash, right of steering column. Plug in your scan tool to verify freeze-frame sensor values.

2. Most Likely Causes on Acura Integra

Historical warranty claims and technical repair bulletins for Acura Integra point to the following failure distribution:

55%
ECT sensor internal short to ground (Acura OEM Part)
25%
Short circuit to ground in ECT signal wiring harness (Acura OEM Part)
12%
Damaged, corroded, or water-contaminated ECT connector (Acura OEM Part)
8%
Faulty PCM / ECM analog input circuit (Acura OEM Part)
* Source: Synthesized from NHTSA ODI field repair telemetry and verified OEM Technical Service Bulletin (TSB) repair tree frequency percentiles for Acura Integra.

3. Step-by-Step DIY Repair Guide for Acura Integra

01
Scan ECT Temperature Data

Read ECT live PID on scanner. If it reads 284°F (140°C) or higher with engine cold, a short to ground exists. on the Acura Integra equipped with 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP).

Required Tool: OBD-II Scanner
02
Unplug ECT Sensor Connector

Unplug sensor connector while watching live data. If temperature drops to -40°F (-40°C), the sensor itself is shorted. on the Acura Integra equipped with 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP).

Required Tool: OBD-II Scanner
03
Inspect Wiring Harness

If reading stays pegged at max with sensor unplugged, inspect harness for pinch points grounding against engine block. on the Acura Integra equipped with 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP).

Required Tool: Digital Multimeter
04
Replace Engine Coolant Temperature Sensor

Allow engine to cool, unscrew old ECT sensor from coolant crossover pipe or thermostat housing, install new OEM sensor with fresh thread sealant. on the Acura Integra equipped with 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP).

Required Tool: 19mm Deep Socket, Ratchet, Coolant Catch Pan
05
Top off Coolant & Clear Codes

Bleed air from cooling system, clear DTCs, and verify normal temperature rise on live data. on the Acura Integra equipped with 1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP).

Required Tool: Coolant Funnel Kit, OBD-II Scanner
Recommended Parts & Testing Tools

Equipment for Diagnosing Acura Integra (P0117)

Prime Fast Delivery & Verified Fitment
Variable Valve Timing (VVT)

VVT Oil Control Solenoid Valve

4.6 / 5.0 (Direct Fit)

Restores accurate camshaft timing and oil pressure regulation on Acura Integra.

$34 – $65 Prime
Check Fitment on Amazon
Sensor Signal Voltage Meter

AstroAI Auto-Ranging Digital Multimeter

4.6 / 5.0 (Best Seller)

Essential for testing 0.1V–5.0V sensor reference signals, ground continuity (<0.20Ω), and harness resistance.

$29.99 Prime
View on Amazon
Top Mobile OBD-II Scanner

BlueDriver Bluetooth Pro OBDII Scan Tool

4.7 / 5.0 (50,000+ Reviews)

Reads and clears enhanced codes (ABS, Airbag, Transmission, Engine) & live freeze-frame telemetry on phone.

Compare OEM & Aftermarket Replacement Sensors for Acura IntegraVerified direct-fit pricing from Denso, Bosch, Motorcraft, and ACDelco on Amazon.
Find Parts on Amazon
* As an Amazon Associate, MazicBay earns from qualifying purchases. Prices & availability subject to change.

Other Common Fault Codes on Acura Integra

Frequently diagnosed powertrain, emissions, and sensor trouble codes logged on the Acura Integra:

4. Acura Integra P0117 FAQs

What causes code P0117 to trigger on a Acura Integra?

On the Acura Integra (1.5L VTEC Turbo (200HP) / 2.0L VTEC Turbo (Type S 320HP)), P0117 is most frequently caused by ECT sensor internal short to ground or Short circuit to ground in ECT signal wiring harness.

Where is the OBD-II port located on my Acura Integra?

On the Acura Integra, the 16-pin DLC diagnostic connector is located Under driver dash, right of steering column. Plug in any standard OBD-II scanner with the ignition in the ON position to read freeze-frame parameters.

Can I safely drive my Acura Integra with code P0117?

No. The ECU thinks the engine is at 280°F+ (overheating) and runs rich or disables cooling fan logic. Given that P0117 carries a High severity rating, we advise avoiding heavy towing or aggressive throttle inputs until sensor readings are verified.