P2004 on Dodge Durango

Intake Manifold Runner Control (IMRC) Stuck Open (Bank 1)

Factory diagnostic protocol and troubleshooting wire for fault code P2004 specifically for the Dodge Durango (2021–2026, 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP)).

Verified OEM Telemetry & Field Repair Tree
Dodge Durango2021–2026
Dodge Durango
SUV3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP)
Reliability
Sensor Voltage Ref
0.1V – 5.0V Ref
Durango SAE Mode $01
ECU Network Bus
500 kbps CAN-FD
ISO 15765-4 Compliant
Drivability Status
Drivable (Short Trip)
Medium urgency level
Est. Repair Cost
$150 - $600 (DIY: $40 - $180)
Parts & Labor DIY
Check P2004 On Another Dodge Model:
Diagnose P2004 on Specific Durango Model Year:

1. Symptoms of P2004 on Dodge Durango

When the Engine Control Module (ECM/PCM) on your Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP)) logs fault code P2004, drivers commonly observe:

Check Engine Light on on Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP))
Sluggish low-RPM acceleration and low-end torque loss on Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP))
Engine runs fine at high highway RPMs (3,500+ RPM) on Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP))
Slightly rough idle or minor intake whistling noise on Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP))
Dodge Durango OBD-II Port Location
The 16-pin diagnostic connector is located Driver lower dash panel near fuse box. Plug in your scan tool to verify freeze-frame sensor values.

2. Most Likely Causes on Dodge Durango

Historical warranty claims and technical repair bulletins for Dodge Durango point to the following failure distribution:

55%
Carbon buildup binding the intake manifold swirl flap runner plates (Dodge OEM Part)
25%
Broken plastic IMRC actuator linkage rod or vacuum diaphragm (Dodge OEM Part)
12%
Faulty electronic IMRC runner control motor / solenoid (Dodge OEM Part)
8%
Cracked vacuum line to IMRC actuator (Dodge OEM Part)
* Source: Synthesized from NHTSA ODI field repair telemetry and verified OEM Technical Service Bulletin (TSB) repair tree frequency percentiles for Dodge Durango.

3. Step-by-Step DIY Repair Guide for Dodge Durango

01
Visually Inspect IMRC Actuator Linkage

Check the mechanical plastic linkage arms at the end of the intake manifold. Verify arms are not popped off or broken. on the Dodge Durango equipped with 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP).

Required Tool: Flashlight, Mirror
02
Test Runner Flap Movement Manually

Move the runner lever by hand. It should spring back smoothly without binding or gritty resistance. on the Dodge Durango equipped with 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP).

Required Tool: None
03
Test IMRC Solenoid / Actuator Motor

Command IMRC open and closed with bi-directional scan tool or check vacuum supply to diaphragm. on the Dodge Durango equipped with 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP).

Required Tool: OBD-II Bi-Directional Scanner or Vacuum Gauge
04
Clean Intake Manifold Carbon or Replace Actuator

Replace the broken linkage/actuator motor or remove manifold to clean heavy carbon deposits around the butterfly flaps. on the Dodge Durango equipped with 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP).

Required Tool: Socket Set, Carburetor Cleaner, Gasket Set
05
Clear DTCs and Verify Runner Operation

Clear trouble codes and confirm low-end acceleration is restored. on the Dodge Durango equipped with 3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP).

Required Tool: OBD-II Scanner
Recommended Parts & Testing Tools

Equipment for Diagnosing Dodge Durango (P2004)

Prime Fast Delivery & Verified Fitment
Direct-Fit Replacement Part

Dodge Durango OEM Replacement Sensor

4.7 / 5.0 (Verified Fit)

Direct-fit replacement assembly engineered to OEM tolerances for Dodge Durango.

$45 – $95 Prime
Check Fitment on Amazon
Sensor Signal Voltage Meter

AstroAI Auto-Ranging Digital Multimeter

4.6 / 5.0 (Best Seller)

Essential for testing 0.1V–5.0V sensor reference signals, ground continuity (<0.20Ω), and harness resistance.

$29.99 Prime
View on Amazon
Top Mobile OBD-II Scanner

BlueDriver Bluetooth Pro OBDII Scan Tool

4.7 / 5.0 (50,000+ Reviews)

Reads and clears enhanced codes (ABS, Airbag, Transmission, Engine) & live freeze-frame telemetry on phone.

Compare OEM & Aftermarket Replacement Sensors for Dodge DurangoVerified direct-fit pricing from Denso, Bosch, Motorcraft, and ACDelco on Amazon.
Find Parts on Amazon
* As an Amazon Associate, MazicBay earns from qualifying purchases. Prices & availability subject to change.

Other Common Fault Codes on Dodge Durango

Frequently diagnosed powertrain, emissions, and sensor trouble codes logged on the Dodge Durango:

4. Dodge Durango P2004 FAQs

What causes code P2004 to trigger on a Dodge Durango?

On the Dodge Durango (3.6L Pentastar V6 (293HP) / 5.7L HEMI V8 (360HP) / 6.4L 392 SRT (475HP)), P2004 is most frequently caused by Carbon buildup binding the intake manifold swirl flap runner plates or Broken plastic IMRC actuator linkage rod or vacuum diaphragm.

Where is the OBD-II port located on my Dodge Durango?

On the Dodge Durango, the 16-pin DLC diagnostic connector is located Driver lower dash panel near fuse box. Plug in any standard OBD-II scanner with the ignition in the ON position to read freeze-frame parameters.

Can I safely drive my Dodge Durango with code P2004?

Yes. Low-end engine torque will feel sluggish, but vehicle is drivable. Given that P2004 carries a Medium severity rating, we advise avoiding heavy towing or aggressive throttle inputs until sensor readings are verified.